BluNODE CL

Current Loop Monitor with 4‑20mA Analog Inputs

$1,500

Industrial monitoring with precision 4‑20mA analog capability. BluNODE CL combines comprehensive base monitoring (20 temperature, 40 Modbus, 4 pulse, 4 CT inputs) with four channels of 4‑20mA current loop inputs—perfect for pressure transducers, flow transmitters, and industrial instrumentation.

Don't need analog? See BluNODE | Also need differential pressure? Add DP Board

Base Monitoring + Analog Precision.

BluNODE CL delivers everything in the base BluNODE—20 temperature sensors, 40 Modbus devices, 4 pulse inputs, and 4 current transformers—plus four channels of 4‑20mA current loop inputs for precision industrial sensors.

Perfect for commissioning agents, MEP engineers, and facility professionals who need to monitor pressure, flow, level, or other parameters using industry‑standard 4‑20mA transmitters.

Key Benefits

Where BluNODE CL Excels

Industrial Process Monitoring Monitor pressure, flow, level, and other process parameters using precision 4‑20mA sensors in manufacturing, processing, or industrial facilities.

Commissioning & Performance Verification Capture high‑resolution performance data using analog sensors to validate system operation and verify equipment meets design specifications.

Advanced Water & Energy Systems Track pressure, flow, and thermal performance using industrial‑grade 4‑20mA transmitters for detailed system analysis and optimization.

Building Automation Integration Integrate 4‑20mA sensors with temperature, pulse, and Modbus monitoring for comprehensive facility oversight.

Professional M&V Projects Deploy for Measurement & Verification studies requiring precise analog instrumentation and professional‑grade data accuracy.

BluNODE CL combines precision analog monitoring with the comprehensive sensor suite of the base BluNODE—giving you complete flexibility to monitor any building system.

4× 4‑20mA Analog Inputs

Industry‑standard current loop inputs for pressure transducers, flow meters, level sensors, and industrial transmitters.

20× Temperature Inputs

Thermistors, RTDs, or thermocouples for comprehensive thermal monitoring.

4× Pulse Inputs

Dry contact or reed switch pulse counting for water, gas, or electric meters.

4× Current Transformer Inputs

Monitor electrical consumption at the circuit or equipment level.

40× Modbus Sensors

RS‑485 Modbus RTU connectivity for existing sensors and building automation equipment.

BluNODE CL Technical Specifications

Technical Specifications

BluNODE CL (Current Loop)

4-20mA Analog Inputs (CL Board)
Analog Input Channels 4 dedicated 4-20mA current loop inputs
Input Range 4-20mA industry-standard current loop
Resolution 16-bit analog-to-digital conversion
Accuracy ±0.1% of full scale
Sensor Power Supply 24VDC available for powering 4-20mA transmitters
Compatible Sensors
  • Pressure transducers
  • Flow transmitters
  • Level sensors
  • Temperature transmitters
  • Any 4-20mA output device
Temperature Monitoring (Base Board)
Temperature Inputs Up to 20 temperature sensors
Sensor Types Thermistors, RTDs, thermocouples
Accuracy ±0.5°C (sensor dependent)
Pulse Monitoring (Base Board)
Pulse Inputs 4 pulse counter channels
Input Types Dry contact, reed switch
Maximum Pulse Rate Up to 100 pulses per second per channel
Power Monitoring (Base Board)
CT Inputs 4 current transformer channels
Measurement Range 0-100A (CT dependent)
Applications Circuit-level or equipment-level electrical monitoring
Modbus Integration (Base Board)
Modbus Sensors Up to 40 Modbus devices
Protocol Modbus RTU over RS-485
Baud Rate 9600-115200 bps (configurable)
Network Connectivity
Wireless Options
  • Wi‑Fi (802.11 b/g/n)
  • Cellular (LTE/4G)
  • LoRaWAN (long‑range, low‑power)
Wired Options RS‑485, Ethernet (optional)
Network Integration Standalone or integrated with BluCORE
Data Processing & Storage
Processing Local edge computing and data logging
Memory Onboard storage for continuous data logging
Logging Interval Configurable from 1 second to hourly (or longer)
Offline Operation Fully functional without internet connection
Power
Input Voltage 12‑24VDC or 100‑220VAC (depending on model)
Power Consumption Low‑power design for extended battery operation
Battery Life Up to 10 years (in low‑power configurations)
Physical Specifications
Enclosure Industrial‑grade, ruggedized housing
Rating NEMA 4X / IP65 (indoor/outdoor rated)
Mounting Options Wall‑mount, pole‑mount, DIN rail, magnetic mount
Operating Temperature ‑20°C to 60°C (‑4°F to 140°F)
Security
Data Encryption AES‑256 encryption for data transmission
Secure Communication TLS/SSL encrypted wireless transmission
Software & Interface
Configuration Web‑based interface or BluCORE integration
Data Access Local retrieval or remote access (when connected)
Alerts Configurable thresholds and notifications
Export CSV, Excel, API integration
Additional Expansion Capability
DP Expansion Board 4× differential pressure sensors (+$700) can be added for HVAC diagnostics
Certifications & Compliance
Standards FCC, CE, UL certified
Environmental RoHS compliant

Add Differential Pressure Monitoring

BluNODE DP Expansion (+$750) Add four built‑in Sensirion SDP810 differential pressure sensors for HVAC airflow diagnostics—combine analog capability with HVAC diagnostics in one device.

Shop DP Expansion Board

Total with both expansions: $2,200 (Base $1,000 + CL $500 + DP $750)

Professional Monitoring. Complete Integration.

Standalone Operation Deploy BluNODE CL as an independent data logger for targeted monitoring with analog sensor capability.

Networked with BluCORE Connect multiple BluNODE CL devices to BluCORE for centralized data aggregation, analysis, and facility‑wide intelligence.

Integrated with BluPULSE Add BluPULSE pulse readers to extend your pulse metering capability beyond the four built‑in inputs.

Mixed Deployment Combine BluNODE CL (for analog applications) with BluNODE and BluNODE DP devices to optimize costs across your facility.

BluNODE CL Hardware

  • BluNODE precision data logger with CL expansion board pre‑installed

  • Power supply and cables

  • Mounting hardware

  • Antenna (for wireless configurations)

  • Quick‑start guide

What’s Included

Software & Interface

  • Local data logging and storage

  • Integration with BluCORE dashboard (when networked)

  • Historical data access and export

  • Alert and notification capabilities

  • API access for custom integrations

Support Options

  • The Starter ($500) — Sensor selection and hardware design guidance

  • The Pro Setup ($100/mo) — Ongoing configuration and remote support

  • The Expert Edge ($250/mo) — Senior expert consultation for advanced deployments

Need Help Selecting Sensors?

BluNODE CL supports 4‑20mA analog sensors plus the full suite of base BluNODE sensors. Our support plans include expert guidance to help you select the right sensors for your monitoring application.

BluNODE CL — $1,500

Ready to Deploy?

Purchase BluNODE CL for immediate deployment with 4‑20mA analog capability, or request a quote for multiple units.

Don't need 4‑20mA analog inputs?
Save $500 with BluNODE base—perfect for temperature, pulse, Modbus, and CT monitoring.

Also need differential pressure monitoring?
Add the DP expansion board for built‑in HVAC differential pressure sensors.

Planning a larger deployment?
Our team can help you design the optimal BluNODE configuration for your facility's monitoring needs.

Volume Pricing Available
Ordering multiple BluNODE devices or planning a campus‑wide deployment? Contact us for volume pricing and deployment consultation.

FAQs

What's the difference between BluNODE CL and BluNODE?

1

BluNODE CL adds four channels of 4‑20mA analog inputs to the base BluNODE. If you need to connect industrial sensors like pressure transducers or flow transmitters, choose BluNODE CL. If you only need temperature, pulse, Modbus, and CT monitoring, the base BluNODE ($1,000) is sufficient.


Can I add the CL board to BluNODE later?

2

Yes! The CL expansion board can be purchased separately ($500) and installed by the customer. However, if you know you'll need analog capability, we recommend BluNODE CL—same total price, pre‑installed and factory tested.


How many 4‑20mA sensors can BluNODE CL support?

3

BluNODE CL has four dedicated 4‑20mA analog input channels, plus all the base BluNODE capabilities (20 temperature, 4 pulse, 4 CT, 40 Modbus).


Can I add differential pressure monitoring to BluNODE CL?

4

Yes! You can add the DP expansion board ($700) to BluNODE CL for complete analog and differential pressure capability in one device.


Can BluNODE CL operate without BluCORE?

5

Yes. BluNODE CL functions as a standalone data logger with local storage and processing. BluCORE integration is optional for centralized monitoring.


We offer three support plans—The Starter, The Pro Setup, and The Expert Edge—covering everything from initial setup to ongoing optimization.

What support is available after purchase?

6

Ready to Add Analog Monitoring to Your Facility?

See how BluNODE CL can deliver precision 4‑20mA analog capability plus comprehensive base monitoring for your building systems.

Questions? We're here to help.